Last additions |
Water Flow Test and Drainage PVCThe drainage PVC has been installed in the proper places to allow the water to exit the site, as evidenced during this flow test. dozerSep 27, 2011
|
|
Walkway PourIn preparation for the walkway pour there is a rebar mesh put in place with spacing every 20 centimeters. dozerSep 27, 2011
|
|
Poured WalkwayThe view after the walkway pour prior to the final smoothing of the concrete. This is hand mix concrete, you can tell it is about the right consistency since there is a minimum of water near the surface, and will become further evident during the final smoothing process. dozerSep 27, 2011
|
|
Electric Conduit Run in Drive Way ColumnsThe yellow conduit is laid in place in the left drive way column. The wire strands are in place to support the wall lighting and the door bell.dozerSep 27, 2011
|
|
Electric Routed to Wall LightingElectric is routed in the upper perimeter wall ring beam. dozerSep 27, 2011
|
|
Heavy Duty Electronic Valve Solenoid ControlMost often you will find water tanks rigged with a toilet float type of on off valve. These cause the pump (in this case a heavy duty submerged franklin) to turn on an off frequently. This wastes electricity and keeps the water 'churning' all the time never giving any impurities time to settle to the bottom. With this type of electronic valve the desired off/on point can be adjusted by moving the middle yellow adjustment tube.dozerSep 27, 2011
|
|
Inside of Pump Station Control BoxThis shows the two circuit breakers (for both pumps) and the control unit (on the left) for the submerged Franklin pump.dozerSep 27, 2011
|
|
ConduitThe yellow PVC conduit is run as needed in the attic above the ceiling to route electric wire to the associated electric appliance (such as fans, lighting, etc.). dozerSep 27, 2011
|
|
Inbound Electric Line tie inThis shows where the inbound electric main line will enter the house, at the roof line above the patio.dozerSep 27, 2011
|
|
Inside view of Junction BoxOnly secure wire fasteners are used in a totally electric tape free installation. This means less to wear out and go wrong over time.dozerSep 27, 2011
|
|
Closed Junction BoxThe sealed junction boxes are indeed secure and neat environment for electric wire connections.dozerSep 27, 2011
|
|
Routing Electric Wire to the Perimeter WallElectrics are routed to the perimeter wall for above wall lighting and the exterior mounted door bell. This particular run of electric will be contained in the drive way pour.dozerSep 27, 2011
|
|