happy builder

 Coolthaihouse Photo Gallery

Construction Photos
Home > House Construction

Most viewed - House Construction
DSCN0463.jpg
PVC Roof Venting78 viewsThe 3/4" PVC roof venting which vents the toilets, sinks and drain pipes. On top of this the septics are also vented, but venting the other appliances helps prevent vacuums and subsequently poor water flow. dozer
IMG_1826.jpg
Attic Walkway78 viewsThis allows for easier access to the attic area. Created from two parallel steel tubing beams with C section rib supports and 20mm grade A plywood as the walkway. dozer
IMG_8732.jpg
Slump Test78 viewsHere is the slump test being performed by a CPAC QA engineer. If the slump is 12 to 14 centimeters the concrete is dryish, 15-17 the concrete is normal and 18 + the concrete is watery. Although 12 to 14 is a bit harder to work it is a stronger and more desirable product to be used in the flooring and ground beam. Workers often prefer 18 + as it is easier to work, without regard to the strength characteristics of the concrete. dozer
IMG_8744.jpg
Concrete being Applied77 viewsThe concrete is delivered from the truck to the desired spot via our 30 centimeter PVC half pieces. This works better than other delivery systems and avoids extra cost required for special equipment. dozer
IMG_8784.jpg
Form Work for Column Pour77 viewsNote that the columns forms are trued using a plumb bob and then locked into place using diagonal 2 x 3 inch wood members. Due to limitations in the amount of form wood, the columns were poured at two different times.dozer
IMG_8774.jpg
Rough Surface Application76 viewsThe surface is roughed after drying slightly in preparation for tile application. dozer
IMG_8999.jpg
Pour of Archways76 viewsThe archways are formed using plywood forms (as shown). The base of the form work is rounded pieces of plywood supported by 2 x 3 inch wood strips. dozer
IMG_9324.jpg
Bathroom Sink Counter76 viewsPreparation for the pour of the bathroom sink. The same method is used as in the kitchen counter, the rebar used in the 6 mm thickness. The concrete will not be poured in the circular area where the sink will go and an open area will be left for the faucet. dozer
IMG_9643.jpg
Kitchen Tiles Diamond76 viewsThe kitchen, patio and bathroom tiles are laid in angled by 45 degrees within an outer border.dozer
IMG_3419.jpg
Roof Overhang Repair75 viewsThe conwood fascia is cut down to allow the roof tiles to be replaced with a tighter fit. dozer
IMG_9017.jpg
Window75 viewsA window showing a horizontal ring beam underneath it, lintel/beam on top and vertical beams to either side. The picture is at an odd angle, the window is perfectly true (but doesn't look like it in the pic). dozer
IMG_9581.jpg
Nearly Finished Counter Cabinets75 viewsThe counter nearly finished. dozer