Home > House Construction > Chok Dee #2 > Electrical

Most viewed - Electrical
IMG_8944.jpg
Electric Wire108 viewsAll electrics in the house are grounded. The copper ground rod is 1.6m and is earthed near the pump station. The red positive, white is negative and green is the ground. Wire is used in various diameters as appropriate, eg. 1.5, 2.5 and 16 (main). dozer
IMG_9712.jpg
Inside of Pump Station Control Box99 viewsThis shows the two circuit breakers (for both pumps) and the control unit (on the left) for the submerged Franklin pump.dozer
IMG_9097.jpg
Junction Box60 viewsThe view of an electrical junction box in the attic. Note that the electrics are securely fastened with plastic affixers which ensures full protection of the electric wires.dozer
IMG_9423.jpg
Installing the Main Electric Panel57 viewsThe main electric panel contains associated breakers running from 10 w up to 32 w depending on the load of devices on the particular station. There are 6 stations in the house. All electric equipment is Bticino Matix.dozer
IMG_9234.jpg
Inside view of Junction Box57 viewsOnly secure wire fasteners are used in a totally electric tape free installation. This means less to wear out and go wrong over time.dozer
IMG_9708.jpg
Heavy Duty Electronic Valve Solenoid Control56 viewsMost often you will find water tanks rigged with a toilet float type of on off valve. These cause the pump (in this case a heavy duty submerged franklin) to turn on an off frequently. This wastes electricity and keeps the water 'churning' all the time never giving any impurities time to settle to the bottom. With this type of electronic valve the desired off/on point can be adjusted by moving the middle yellow adjustment tube.dozer
IMG_9107.jpg
Inbound Electric Line tie in55 viewsThis shows where the inbound electric main line will enter the house, at the roof line above the patio.dozer
IMG_9299.jpg
Electric Routed to Wall Lighting55 viewsElectric is routed in the upper perimeter wall ring beam. dozer
IMG_9245.jpg
Routing Electric Wire to the Perimeter Wall54 viewsElectrics are routed to the perimeter wall for above wall lighting and the exterior mounted door bell. This particular run of electric will be contained in the drive way pour.dozer
IMG_9262.jpg
Electric Conduit Run in Drive Way Columns54 viewsThe yellow conduit is laid in place in the left drive way column. The wire strands are in place to support the wall lighting and the door bell.dozer
IMG_9452.jpg
Typical Power Point Installation53 viewsThis shows a power point with a inbound cable co ax TV junction. There is also a telephone jack. Each power point and switch box is temporarily covered with this plastic to prevent splatter during painting and other construction activities. dozer
IMG_8945.jpg
Electric line being run to Pump52 viewsThis line will be routed to the pump station on the exterior of the house. For electric which is run through the garden area a protective concrete casing will be poured over the conduit.dozer