IMG_8830.jpg
202 viewsThe frame work for the roof structure is box section 4 inch x 2 inch heavy 3.2 mm thick metal sections. There are columns at even intervals so a more extensive truss system is unnecessary (as opposed to Chok Dee #1).dozer
IMG_9601.jpg
Lanko K10 waterproofing181 viewsAny roof not dry teched will need a waterproofing treatment at the ridges even after any visible imperfections are caulked. This house used this product over every section of ridge joint. dozer
IMG_8908.jpg
Basic Roof Structure123 viewsThe basic roof structure with the battens fixed at periodic intervals to support the Cpac roof tiles. dozer
IMG_8895.jpg
Wood to Support the Facia Board118 viewsWood is installed within the box sections of the roof structure to support the facia board which will be affixed. These members still to be painted after the box sections were cut. dozer
IMG_8847.jpg
Hip Roof Structure112 viewsThe raw hip roof structure. The key members are the 3.2 mm thick steel with intermediate sections done in the 2.0 mm thick steel. Box sections are used throughout, no C sections. dozer
IMG_8934.jpg
Galvanized Sheeting for Roof Valley111 viewsMost of the problems with CPAC concrete roof tiles come from inadequate valley material or poorly done ridges. It is easy to get the wrong stuff, just go to any supply store and ask for the valley material that everyone uses. This is the 1 meter wide material, formed in the center for water run-off, roofs with this as valley material (properly installed) don't have problems. dozer
IMG_8875.jpg
Raw Weld106 viewsA raw (prior to rust painting) weld. The 3.2 mm thick electrode rods are used (as opposed to the 2.6 mm variety) for a heavy duty weld. All welds should be inspected when ever possible. dozer
IMG_9251.jpg
Ceiling Structure103 viewsThe C Lie suspension rails used are the heavier grade and are spaced at about 60 centimeters by 1 meter intervals. Note the tiered ceiling section on the left side (to support the two levels of ceiling structure).dozer
IMG_8924.jpg
Rust Painted Weld101 viewsAfter a few days of raw welds any good team will automatically paint the welds. Just a point of procedure to verify. dozer
IMG_8986.jpg
Properly Installed Bird Stop100 viewsThis bird stop has about the right clearance, a snug fit is required or otherwise you will get unwanted entry points. dozer
IMG_9595.jpg
Roof Inspection100 viewsDon't fool yourself into thinking CPAC roof tiles are totally dummy proof. Leaks often occur at the ridge lines and valleys. A inspection during a rain cycle ensures compliance. This roof had no leaks, hurray!dozer
IMG_9273.jpg
Drywall Gypsum Board100 viewsThe sheets are screwed into the c lie suspension rails. dozer