happy builder

 Coolthaihouse Photo Gallery

Construction Photos
Home > User galleries

Last additions - User galleries
P3261934.JPG
26 March 2009A shot here of the now installed raceway but before the conduit is connected to the bottom of the channel with bushings.pklongballMar 26, 2009
P3261931.JPG
26 March 2009And again some arrows point to another section of raceway and the method to hang it. Some holes are drilled into the steel of the roof and they secure it with big "pop" rivets. This will make his cabling job a breezepklongballMar 26, 2009
P3261930.JPG
26 March 2009In this shot I am pointing some added arrows to the now installed wireway. Sparky is doing a fine job to this point in how he is going about the install of my wiring.pklongballMar 26, 2009
P3261926.JPG
26 March 2009So we come to the panel with no cover and no breakers installed. This is a 3 phase panel in case anyone is wonderingpklongballMar 26, 2009
P3261927.JPG
26 March 2009Another view of the panel with door off and you can see the spot for the main breaker and 24 MCB'spklongballMar 26, 2009
P3261928.JPG
26 March 2009Our new Square "D" Classic load centerpklongballMar 26, 2009
P3261933.JPG
26 March 2009Here we have the start of installing the wireway. We are using 2 x 4 by 2 meter sections. These are connected to each other as needed to form the raceway for all the power cabling. Various hand and electric tools are used in the process of assembling the sections.pklongballMar 26, 2009
P3261932.JPG
26 March 2009This shot is Sparkie's right hand man installing a section of the wireway metal chase we decided to use instead of the standard conduit and boxes. This chase will join all areas of the ceiling area together to allow cables to be pulled to any conduit stubs from the main load center as well as travel to other points.pklongballMar 26, 2009
P3231924.JPG
23 March 2009The other side of the bed gets a switch and plug in the same box . Most bed lamps only have a 2 bladed plug so I thought a good deal here.pklongballMar 24, 2009
P3231925.JPG
23 March 2009This pair of boxes will have a plug and switch set up so we can plug in a bedside light and switch it on/off without struggling to find the lamp switch.pklongballMar 24, 2009
P3231920.JPG
23 March 2009Here we have a pair of wall boxes. One is for a duplex plug and the other for the TV/Tel cables. They each have a respective conduit running up the wall cavity.pklongballMar 24, 2009
P3231921.JPG
23 March 2009This is the exterior living room wall about half way up and you can see the double blocks and cavity. This wall is almost ready for form wood to make the window and beampklongballMar 24, 2009